Tech specs
FireProtect 2 RB (Heat/Smoke/CO) UL Jeweller
Wireless combined heat, smoke, and CO detector with replaceable batteries
Devices compatibility
CheckCommunication
Jeweller communication technology
Proprietary wireless technology for alarm and event transmission.
Key features:
- Two-way communication.
- Protection against device spoofing.
- Block encryption featuring a dynamic key.
- Instant notifications.
- Remote control and configuration in Ajax apps.
Frequency band
905.0–926.5 MHz
Certified by UL/ULC standards.
Maximum effective radiated power (ERP)
up to 20 mW
Automatic power control to reduce power consumption and radio interference.
Radio signal modulation
GFSK
Radio signal range
up to 5,550 ft
Between the detector and a hub (or range extender) in an open space.
Encrypted communication
All stored and transmitted data are protected by block encryption featuring a dynamic key.
Frequency hopping
To prevent radio interference and jamming.
Sensitive elements
smoke sensor
heat sensor
CO (carbon monoxide) sensor
Smoke detection
Sensitive element
double-spectrum optical sensor
Detects smoke by the size of particles in the air.
Patented smoke chamber
Protects the smoke sensor from dust, dirt, and insects.
Dangerous temperature detection
Sensitive element
for low temperature detectors
Requirements of UL 521.
High temperature alarm
at temperatures above 135 °F
Carbon monoxide (CO) detection
Sensitive element
chemical CO sensor
Alarm for exceeding CO level
70 ppm (0.007%) — in 60–240 minutes
150 ppm (0.015%) — in 10–50 minutes
400 ppm (0.04%) — in 4–15 minutes
CO concentration of 400 ppm (0.04%) within 3 hours can be life-threatening. The detector stops notifying about the dangerous level of carbon monoxide when the concentration drops to 70 ppm (0.007%) within 1 minute.
Sensor service life
10 years
After 10 years of operation, the detector must be replaced with a new one.
Additional features
Built-in siren
85 dB volume at a distance of 9 ft
Sound notification of alarms. Active until the reason for triggering is eliminated or until the user disables notification.
Interconnected Fire Detectors Alarm
All fire detectors in the system turn on built-in sirens if at least one detector registers an alarm. An interconnected fire alarm is activated within one “hub — detector” polling interval but no more than 20 seconds later.
LED indication
yellow indicates malfunctions
An LED indicator on the device enclosure lights up when malfunctions are detected, such as discharged batteries, contamination of the smoke chamber, or end of the service life.
red indicates fire alarms
An LED indicator on the device enclosure lights up when the detector registers a fire alarm.
Button on the front panel of the detector
In normal mode, pressing the button starts the smoke chamber test. In the case of an alarm or malfunction, pressing the button turns off the detector sound notification.
Recommendations
The device is designed for indoor installation only. SmartBracket mounting panel enables adjusting the position of the detector after installation.
Sabotage protection
Tamper alarm
Alerts of attempts to detach the detector from the surface or remove it from the mounting panel.
Protection against spoofing
device authentication
Communication loss detection
after 36 s
Detection time depends on the Jeweller or Jeweller/Fibra settings and can’t exceed 200 s.
Power supply
Batteries
2 × CR123A (pre-installed)
3 V⎓, 1,600 mAh
Manufacturer: Ajax Systems
Up to 5 years of battery life.
Enclosure
Dimensions
4.88″ × 4.88″ × 1.77″
Weight
9.68 oz
Operating temperature range
from 32°F to 100.4 °F
Certified by UL/ULC standards.
Operating humidity
up to 80%
Protection class
IP20
Colours
Black
White
Complete set
FireProtect 2 RB (Heat/Smoke/CO) UL Jeweller
SmartBracket mounting panel
Installation kit
2 × CR123A battery (pre-installed)
Quick start guide
Certification and compliance with standards
FireProtect 2 RB (Heat/Smoke/CO) UL Jeweller
FireProtect 2 RB (Heat/Smoke/CO) UL Jeweller
FCC ID
Certification Issued Under the Authority of the Federal Communications Commission
2AX5VFISMHTCJ1UL
IC ID
Certificate issued by MiCOM Labs
26860-FISMHTCJ1UL
CSA
Certificate issued by CSA Group Testing & Certification Inc.
ANSI/UL 62368-1 Ed. 3
CSA C22.2 No. 62368-1:19 Ed. 3
Standard for Safety Smoke Detectors for Fire Alarm Systems
Certificate issued by Intertek Group plc.
UL 268:2023 Ed.8
CAN/ULC S529:2023 Ed.5
Standard for Safety Gas and Vapor Detectors and Sensors for Fire Alarm Systems
Certificate issued by Intertek Group plc.
UL 2075:2013 Ed.2+R:04Aug2023
CAN/ULC S588:2017 Ed.1+R1