Tech specs
Bypass (Dimmer) [55]
Bypass for dimmer light switch
Compatibility
The bypass is also compatible with third-party dimmers. Carefully read the manufacturer’s instructions for third-party dimmer, before connecting Bypass (Dimmer) [ 55 ].
Installation
Connection
in parallel with the lighting appliance
The device can be installed in a lamp junction box.
Recommendations
The device is designed for indoor use only. A professional electrician should install the device.
Power supply
Voltage
230 V, 50 Hz
The device is connected in parallel with the lighting appliance.
Average consumption
up to 1 W
Product
Enclosure dimensions
1.22″ × 0.94″ × 0.43″
Wires length
3.54″ ± 0.02″
Weight
0.25 oz
Operating temperature range
from 14 °F to 104 °F
Operating humidity
up to 75% with no condensation
Form factor of the compatible dimmer
European type (55)
Complete set
Bypass (Dimmer) [ 55 ]
Quick start guide
Certification and compliance with standards
Bypass (Dimmer) [55]
Bypass (Dimmer) [55]
Radio Equipment Directive (RED)
Certificate issued by TIMCO Engineering, Inc.
EN 300 220-1 V3.1.1
EN 300 220-2 V3.2.1
Restriction of Hazardous Substances Directive (RoHS)
Test report issued by Shenzhen NTEK Testing Technology Co.
EN IEC 63000:2018
Low Voltage Directive (LVD)
Certificate issued by TIMCO Engineering, Inc.
EN 62479:2010
EN IEC 60669-2-1:2022 / A11:2022
EN 60669-2-5:2016
EN 60669-1:2018
Electromagnetic Compatibility Directive (EMC)
Certificate issued by TIMCO Engineering, Inc.
EN 301 489-1 V2.2.3
EN 301 489-3 V2.1.1
EN 55032:2015 / A1:2020
EN 55035:2017 / A11:2020
EN IEC 61000-3-2:2019 / A1:2021
EN 61000-3-3:2013 / A2:2021
PSTI UK
Schedule 1