Tech specs
Transmitter Fibra
Soon to be: Superior Transmitter Fibra
Wired module to integrate one third-party device into the Ajax system
Devices compatibility
CheckCommunication
Fibra communication technology
Proprietary wired communication technology. Fibra combines the reliability of wires with the freedom of radio connection.
Key features:
- Two-way communication.
- Advanced anti-sabotage.
- Block encryption featuring a dynamic key.
- Instant notifications.
- Remote configuration in the Ajax apps.
Line connection
4-core cable
Connection
to any point of the Fibra line
Transmitter Fibra can be installed after a hub, detector, keypad, or siren.
Fibra line length
up to 6,500 ft
When using the U/UTP cat.5 twisted pair cable.
Encrypted communication
All stored and transmitted data are protected by block encryption featuring a dynamic key.
Wired devices connection
Supported configurations
- roller shutter
- tamper
- wired device with 15 event types
Connector pins
- 12V — power supply output for a wired detector
- GND — ground
- Z1–Z2 — inputs for connecting a wired detector
- COM — common input for connecting signal contacts of a wired detector
Transmitter Fibra has 2 inputs (Z1 and Z2) to connect the wired detector using the AATT (i.e., Alarm Alarm Tamper Tamper) scheme.
Type of connection
NO, NC, EOL, 2EOL, 3EOL
With EOL total resistance from 1 kΩ to 40 kΩ with a 100 Ω increment.
Cable length
up to 3 m
When using a signal cable with a 0.22 mm² copper conductor.
Operation mode
pulse, bistable
Event types
15 event types of wired devices
- Tamper alarm
- Intrusion
- Fire
- Auxiliary alarm
- Panic button
- Gas alarm
- Malfunction
- Leakage
- Glass break
- High temperature
- Low temperature
- Masking
- Duress code (opening)
- Vibration (seismic sensor)
- Custom
Adjusted by a PRO or a user with admin rights in the Ajax app.
Recommendations
Transmitter Fibra should be installed inside the wired detector case. The module requires a space with the following minimum dimensions: 1.57″ × 0.59″ × 0.48″
Sabotage protection
Protection against spoofing
device authentication
Instant line damage detection
Valid for EOL, 2EOL, or 3EOL connections.
Communication loss detection
after 36 s
Between the hub and Transmitter Fibra. It can be changed in the hub settings.
Power supply
Fibra line
7–30 V⎓, up to 200 mA
The hub powers the module.
Output to the connected wired device
10.5–15 V⎓, up to 50 mA (total maximum current consumption)
One power supply line from Transmitter Fibra.
Board
Dimensions
1.57″ × 0.59″ × 0.48″
Weight
0.21 oz
Operating temperature range
from −13 °F to +122 °F
Operating humidity
up to 75%
Electric shock protection
Class II
Complete set
Transmitter Fibra
Accessory 5-pin cable
Quick start guide
Certification and compliance with standards
Transmitter Fibra
Transmitter Fibra
Compliance with the security alarm standards
Certificate issued by TREZOR TEST s.r.o.
EN 50131-1:2006 / A1:2009 / A2:2017/ A3:2020
EN 50131-3:2009
PD 6662:2017*
Security Grade (SG)
Certificate issued by TREZOR TEST s.r.o.
3
Restriction of Hazardous Substances Directive (RoHS)
Test report issued by Shenzhen NTEK Testing Technology Co.
EN IEC 63000:2018
Electromagnetic Compatibility Directive (EMC)
Certificate issued by MiCOM Labs
EN 55032:2015+A1:2020
EN 55035:2017+A11:2020
Environmental class according to EN 50131
Certificate issued by TREZOR TEST s.r.o.
II
PSTI UK
Schedule 1